At the junction of sewers

A. Top of smaller sewer is kept lower

B. Top of larger sewer is kept lower

C. Tops of both the sewers are at the same level

D. None of these

Answer: Option D

Solution (By Examveda Team)

At the junction of two sewers of different diameters, the standard principle is that the soffit (top inside surface) of the smaller sewer should not be lower than the soffit of the larger sewer. This arrangement helps maintain proper hydraulic conditions and reduces the possibility of backwater entering the smaller sewer.

Option A: Top of smaller sewer is kept lower
Incorrect. The smaller sewer's top should not be lower than the top of the larger sewer.

Option B: Top of larger sewer is kept lower
Incorrect as a general statement. The standard rule is expressed in terms of the smaller sewer's soffit being at the same level or higher than that of the larger sewer, rather than stating that the larger sewer's top is always kept lower.

Option C: Tops of both the sewers are at the same level
Incorrect. The tops may be at the same level in some arrangements, but this is not the general rule for every sewer junction.

Option D: None of these
Correct, because none of the first three options states the standard rule accurately and generally.

Hence, Option D — None of these is the correct answer.

This Question Belongs to Civil Engineering >> Waste Water Engineering

Join The Discussion

Comments (3)

  1. Riju Chakraborty
    Riju Chakraborty:
    3 weeks ago

    At sewer junction
    invert of incoming sewer → near crown of outgoing sewer.

  2. Hamza Qasim
    Hamza Qasim:
    5 years ago

    @Nandure Asha
    For
    d= 100mm, 1:60
    d= 150mm, 1:100
    d= 225mm, 1:120

  3. Nandure Asha
    Nandure Asha:
    7 years ago

    If the diameter of a sewer is 100 mm, the gradient required for generating self cleansing velocity is?
    Please solve this problem