Examveda

For sewer mains of 0.5 to 1 m diameter, the ratio of maximum daily sewage flow to the average daily sewage flow is assumed

A. 1.5

B. 2.0

C. 2.5

D. 3.0

Answer: Option B


This Question Belongs to Civil Engineering >> Waste Water Engineering

Join The Discussion

Comments (1)

  1. Riju Chakraborty
    Riju Chakraborty:
    1 month ago

    Sewer diameter=Qmax/Qavg
    Up to 0.5 m =2.5
    0.5–1.0 m =2.0
    1.0–1.25 m =1.5–2.0
    More than 1.25 m =1.5