Examveda

The spacing of man holes along a straight portion of a sewer is 300 m, the diameter of the sewer may be

A. 0.9 cm

B. 1.2 m

C. 1.5 m

D. > 1.5 m

Answer: Option D


This Question Belongs to Civil Engineering >> Waste Water Engineering

Join The Discussion

Comments (1)

  1. Riju Chakraborty
    Riju Chakraborty:
    1 month ago

    Diameter
    < 300 mm → spacing about 30 m
    300–600 mm → 45–75 m
    600–900 mm → 75–100 m
    900–1500 mm → 100–150 m
    1500 mm → 150–300 m